GAC2500 - Power Consumption

  • Updated on September 14, 2023

This document is a technical bulletin describing power consumption details for GAC2500.

GAC2500 can be powered using Universal power supply:
Input AC 100-240V 50/60Hz; Output 12VDC, 2A (24W)

TEST CONDITION TERMINOLOGY

The following test condition terminology was used in table 1.

  1. Idle State
  • The system has completed the boot-up process.
  • The system is set with default factory settings without any change.
  • No devices connected to auxiliary ports.
  1. Work State
  • The system was setup as described in the Idle State.
  • The system established 2 IP calls via WAN port. Bluetooth connected to other device and volume level set to maximum.
  1. Power Not Exceed
  • The system established 6 IP calls via WAN port. Bluetooth connected to other device and volume level set to maximum.
  • Other Peripherals and settings as Work State condition.
  • Capacitive touch screen operated during test.

Power Dissipation

Table 1: Power Dissipation and Advertisement

Product

Power  Adapter (12VDC)

PoE (48VDC)

Class Advertisement (IEEE 802.3at)

Idle State

(W)

Work State

(W)

Max Power Consumption

(W)

Idle State

(W)

Work State

(W)

Max Power Consumption

(W)

GAC2500

3.494

4.307

9.305

4.390

5.210

11.136

4

PD Power Classification

Table 2: PD Power Classification (IEEE 802.3af)

Class

Usage

Max Power Range used by the PD (phone)

0

Default

0.44 to 12.95W

1

Optional

0.44 to 3.84W

2

Optional

3.84 to 6.49W

3

Optional

6.49 to 12.95W

4

Optional

Reserved for future use

(for example: IEEE802.3at)

Table 3: PD Power Classification (IEEE 802.3at)

Class

Usage

Max Power Range used by the PD (phone)

0

Default

0.44 to 12.95W

1

Optional

0.44 to 3.84W

2

Optional

3.84 to 6.49W

3

Optional

6.49 to 12.95W

4

Optional

12.95 to 25.5W

Was this article helpful?

Need Support?
Can’t find the answer you’re looking for? Don’t worry we’re here to help!
Contact Support

Leave a Comment