Power Dissipation

ITEM

PRODUCT

Power Adapter (5.12VDC)

POE (46.9VDC)

Class Advertise-ment (IEEE 802.3af)

Idle State

Work State

Not To Exceed

Idle State

Work State

Not To Exceed

Power (W)

Power (W)

Power (W)

Power (W)

Power (W)

Power (W)

1

BT200


2.450

2.780

2.880

N/A

N/A

N/A

N/A

2

GXP280

1.950

2.038

2.253

N/A

N/A

N/A

N/A

3

GXP285


1.950

2.038

2.253

2.592

2.736

3.200

1

4

GXP1200

2.430

2.890

2.890

4.890

5.460

5.460

0

5

GXP2000

2.420

3.140

3.190

5.080

5.890

5.940

0

6

GXP2000 + 1EXT

3.010

3.640

3.680

5.700

6.510

6.560

0

7

GXP2000 + 2EXT

3.470

4.130

4.140

6.320

7.140

7.230

0

8

GXP2010

2.490

2.840

3.110

3.450

3.990

4.180

0

9

GXP2010 + 1EXT

2.920

3.400

3.640

3.840

4.520

4.670

0

10

GXP2010 + 2EXT

3.400

3.900

4.190

4.470

5.010

5.150

0

11

GXP2020

2.950

3.750

3.820

3.850

4.760

4.960

0

12

GXP2020 + 1EXT

3.400

4.270

4.370

4.530

5.250

5.440

0

13

GXP2020 + 2EXT

3.930

4.830

4.920

4.910

5.880

5.980

0

14

GXP2120

1.413

1.567

2.509

1.923

2.157

3.189

2

15

GXP2120 + 1EXT

1.859

2.043

3.256

2.439

2.720

4.174

2

16

GXP2120 + 2EXT

2.355

2.529

3.994

3.095

3.424

5.159

2

17

GXP2110

1.423

1.556

2.452

1.970

2.111

3.236

2

18

GXP2110 + 1EXT

1.869

2.007

3.190

2.486

2.673

4.174

2

19

GXP2110 + 2EXT

2.345

2.473

3.917

3.095

3.330

5.206

2

20

GXP1100

0.999

1.267

1.590

N/A

N/A

N/A

N/A

21

GXP1105

0.999

1.267

1.590

1.459

1.816

2.032

2

22

GXP1160

1.791

2.081

3.129

N/A

N/A

N/A

N/A

23

GXP1165

1.791

2.081

3.129

2.544

2.986

4.416

2

24

GXP1400

1.561

1.869

2.107

N/A

N/A

N/A

N/A

25

GXP1405

1.561

1.869

2.107

2.260

2.672

2

26

GXP1450

1.834

2.053

2.391

2.668

2.910

3.686

2

27

GXP2100

2.036

2.360

3.219

2.750

3.730

4.300

2

28

GXP2124

1.193

1.933

2.822

1.989

3.138

3.918

2

29

GXP1610

0.665

1.336

1.928

N/A

N/A

N/A

30

GXP1620

0.680

1.378

1.992

N/A

N/A

N/A

31

GXP1625

0.680

1.378

1.992

1.070

2.051

2.702

1

32

GXP1628

0.815

1.414

2.080

1.216

2.108

2.710

1

33

GXP1630

0.870

1.483

2.102

1.356

2.195

2.803

1

34

GXP2200

3.678

3.920

12.382

4.511

4.705

14.599

0

35

GXP2200 + 1EXT

4.918

9.135

5.855

10.946

0

36

GXP2200 + 2EXT

5.916

10.133

7.004

12.095

0

37

GXP2200 + 3EXT

6.914

11.131

8.153

13.245

0

38

GXP2200 + 4EXT

7.912

12.129

9.303

14.394

0

39

GXP2140

1.442

2.161

5.490

2.290

2.626

6.789

3

40

GXP2140 + 1EXT

2.660

3.520

6.619

3.420

4.430

8.027

3

41

GXP2140 + 2EXT

3.560

4.420

7.541

4.590

5.390

9.260

3

42

GXP2140 + 3EXT

4.510

5.330

8.754

5.650

6.340

10.419

3

43

GXP2140 + 4EXT

5.470

6.200

9.674

6.710

7.610

11.802

3

44

GXP2160

1.454

2.171

6.003

2.400

2.814

7.487

3

45

GXP2130

1.870

1.955

2.086

1.970

2.296

2.408

2

46

GXP2170

1.879

3.762

7.188

3.447

5.145

9.571

3

47

GXP2170 + 4EXT

5.785

7.574

11.009

8.223

9.937

14.171

3

48

GXP2135

1.176

1.656

2.748

1.968

2.160

3.504

2

PD Power Classification

Class

Usage

Max Power Range Used By PD (Phone)

0

Default

0.44 – 12.95W

1

Optional

0.44 – 3.84W

2

Optional

3.84 – 6.49W

3

Optional

6.49 – 12.95W

4

Not Allowed

Reserved for future use (ex: IEEE802.3af).

Note

  1. EXT is a GXP2000/2010/2020/2200EXT Extension Module.
  2. For “Class Advertisement”, refer to Table 2 for IEEE 802.3af Classifications.
  3. The power for GXP2010/2020 EXT is supplied by the device directly.

Test Condition Terminology

The following test condition terminology was used in Table 1:

  • Idle State
    • The phone has completed the boot-up process.
    • The SIP application was running PCMA codec with SRTP.
    • The idle configuration was shown on the LCD.
    • LCD backlight (normal brightness).
  • Work State
    • The phone was set up as described in Idle State.
    • The maximum number of calls was established for each Unit Under Test (UUT).
    • The hands-free mode was activated for each UUT and set to maximum volume.
    • The LCD displayed the Diagnostic screen during the test.
    • BT200/GXP280 just used hands-free mode.
  • Power Not To Exceed
    • +nEXT means connect to n Extension Module(s), n = 1,2,3,4.
    • EXT work condition: all indicator LEDs are lighting.
    • External USB device in Max Power.
    • Ring state or called state.

Was this article helpful?

Need Support?
Can’t find the answer you’re looking for? Don’t worry we’re here to help!
Contact Support

Leave a Comment