GWN780x(P) L2+ - Quick Installation Guide

  • Updated on August 18, 2023

OVERVIEW

The GWN7800 series are Layer 2+ managed network switches that allow small-to-medium enterprises to build scalable, secure, high-performance, and smart business networks that are fully manageable. It supports advanced VLAN for flexible and sophisticated traffic segmentation, advanced QoS for prioritization of network traffic, IGMP Snooping for network performance optimization, and comprehensive security capabilities against potential attacks. The PoE models provide smart dynamic PoE output to power IP phones, IP cameras, Wi-Fi access points, and other PoE endpoints. The GWN7800 series can be managed in a number of ways, including the local web user interface of the GWN7800 series switch. The series is also supported by GWN.Cloud, Grandstream’s cloud and on-premise Wi-Fi management platform. The enterprise-grade GWN7800 series are the ideal managed network switches for small-to-medium businesses.

PACKAGE CONTENTS

GWN780x Package Contents

GWN780X PORTS

GWN7801/GWN7801P

GWN7801/GWN7801P Ports

No.

Port & LED

Description

1

Port 1-8

8x Ethernet RJ45 (10/100/1000Mbps), used for connecting terminals.

Note: GWN7801P Ethernet ports support PoE and PoE+.

2

1-8

Ethernet ports’ LED indicators

3

Port SFP 1/2

2x 1000Mbps SFP ports

4

SFP 1/2

SFP ports’ LED indicators

5

RESET

Factory Reset pinhole. Press for 5 seconds to reset factory default settings

6

SYS

System LED indicator

7

CONSOLE

1x Console port, used for connecting managing PC

8

100-240 VAC 50-60Hz

Power socket

9

Lightning protection grounding post

GWN7801(P) Ports and LEDs

GWN7802/GWN7802P

GWN7802/GWN7802P Ports

No.

Port & LED

Description

1

Port 1-16

16x Ethernet RJ45 (10/100/1000Mbps), used for connecting terminals.

Note: GWN7802P Ethernet ports support PoE and PoE+.

2

1-16

Ethernet ports’ LED indicators

3

Port SFP1/2/3/4

4x 1000Mbps SFP ports

4

SFP 1/2/3/4

SFP ports’ LED indicators

5

RESET

Factory Reset pinhole. Press for 5 seconds to reset factory default settings

6

SYS

System LED indicator

7

CONSOLE

1x Console port, used for connecting managing PC

8

100-240 VAC 50-60Hz

Power socket

9

Lightning protection grounding post

10

Fan

1x Fan

GWN7802(P) Ports and LEDs

GWN7803/GWN7803P

GWN7803/GWN7803P Ports

No.

Port & LED

Description

1

Port 1-24

24x Ethernet RJ45 (10/100/1000Mbps), used for connecting terminals. Note: GWN7803P Ethernet ports support PoE and PoE+.

2

1-24

Ethernet ports’ LED indicators

3

Port SFP1/2/3/4

4x 1000Mbps SFP ports

4

SFP 1/2/3/4

SFP ports’ LED indicators

5

RESET

Factory Reset pinhole. Press for 5 seconds to reset factory default settings

6

SYS

System LED indicator

7

CONSOLE

1x Console port, used for connecting managing PC

8

100-240 VAC 50-60Hz

Power socket

9

Lightning protection grounding post

10

Fan

2x Fan

GWN7803(P) Ports and LEDs

INSTALLATION

Install on the Desktop

GWN780x(P) Desktop Installation
  1. Place the bottom of the switch on a sufficiently large and stable table.
  2. Peel off the rubber protective paper of the four footpads one by one, and stick them in the corresponding circular grooves at the four corners of the bottom of the case.
  3. Flip the switch over and place it smoothly on the table.

Install on the Wall

Note:

GWN7801(P) require the Extended Rack Mounting Kits

GWN780x(P) Wall Installation
  1. Use the matching screws (KM 3*6) to fix the two L-shaped rack-mounting kits (rotated 90°) on both sides of the switch.
  2. Stick the switch port up and horizontally on the selected wall, and mark the position of the screw hole on the L-shaped rack-mounting kits with a marker. Then, drill a hole at the marked position with an impact drill, and drill the expansion screws(prepared by yourself) into the drilled hole in the wall.
  3. Use a screwdriver to tighten the screws (prepared by yourself) that have passed through the L-shaped rack-mounting kits to tighten the expansion solenoids to ensure that the switch is firmly installed on the wall.

Install on a 19″ Standard Rack

Note:

GWN7801(P) require the Extended Rack Mounting Kits

GWN780x(P) L-shaped rack-mounting Installation
  1. Check the grounding and stability of the rack.
  2. Install the two L-shaped rack-mounting in the accessories on both sides of switch, and fix them with the screws provided (KM 3*6).
GWN780x(P) Standard Rack Installation
  1. Place the switch in a proper position in the rack and support it with the bracket.
  2. Fix the L-shaped rack mounting to the guide grooves at both ends of the rack with screws(prepared by yourself) to ensure that the switch is stably and horizontally installed on the rack.
Note:

To avoid high temperatures and keep the device cool, sufficient space should be left around the switch for heat dissipation. The air inlet of the switch cannot face or be close to the air outlet of other devices.

GWN7802P – Air inlet/outlet
GWN7803P – Air inlet/oulet

POWERING AND CONNECTING GWN780X(P)

Grounding the Switch

Grounding the Switch
  1. Remove the ground screw from the back of the switch, and connect one end of the ground cable to the wiring terminal of the switch.
  2. Put the ground screw back into the screw hole, and tighten it with a screwdriver.
  3. Connect the other end of the ground cable to another device that has been grounded or directly to the terminal of the ground bar in the equipment room.

Powering on the Switch

Connect the power cable and the switch first, then connect the power cable to the power supply system of the equipment room

Powering on the Switch

Connecting Power Cord Anti-Trip

In order to protect the power supply from accidental disconnection, it’s recommended to purchase a power cord anti-trip for installation.

Connecting Power Cord Anti-Trip (Optional) – part 1
  1. Place the smooth side of the fixing strap towards the power outlet and insert it into the hole on the side of it.
Connecting Power Cord Anti-Trip (Optional) – part 2
  1. After plugging the power cord into the power outlet, slide the protector over the remaining strap until it slides over the end of the power cord.
  2. Wrap the strap of the protective cord around the power cord and lock it tightly. Fasten the straps until the power cord is securely fastened.

Connect to RJ45 Port

Connect to RJ45 Port
  1. Connect one end of the network cable to the switch and the other end to the peer device.
  2. After powering on, check the status of the port indicator. If on, it means that the link is connected normally; if off, it means the link is disconnected, please check the cable and the peer device whether are enabled.

Connect to SFP Port

The installation process of the fiber module is as follows:

Connect to SFP Port
  1. Grasp the fiber module from the side and insert it smoothly along the switch SFP port slot until the module is in close contact with the switch.
  2. When connecting, pay attention to confirm the Rx and Tx ports of the SFP fiber module. Insert one end of the fiber into the Rx and Tx ports correspondingly, and connect the other end to another device.
  3. After powering on, check the status of the port indicator. If on, it means that the link is connected normally; if off, it means the link is disconnected, please check the cable and the peer device whether is enabled.
Notes:

  • Please select the optical fiber cable according to the module type. The multi-mode module corresponds to the multi-mode optical fiber, and the single-mode module corresponds to the single-mode optical fiber.
  • Please select the same wavelength optical fiber cable for connection.
  • Please select an appropriate optical module according to the actual networking situation to meet different transmission distance requirements.
  • The laser of first-class laser products is harmful to the eyes. Do not look directly at the optical fiber connector.

Connect to Console Port

Connect to Console Port
  1. Connect the RJ45 end of the console cable to the console port of the switch.
  2. Connect the other end of the console cable to the DB9 male connector or USB port to the PC.

ACCESS AND CONFIGURE

Note:

If no DHCP server is available, the GWN7800 default IP address is 192.168.0.254.

Login using the Console port

  1. Use the console cable to connect the console port of the switch and the serial port of the PC.
  2. Open the terminal emulation program of the PC (e.g. SecureCRT), and enter the default username and password to log in. (The default administrator username is “admin” and the default random password can be found on the sticker on the GWN7800 switch).
Note:

The baud rate needs to be set to 115200.

Login Remotely using SSH

  1. Enter “cmd” in PC/Start.
  2. Enter ssh <gwn7800_IP> in the cmd window.
  3. Enter the default username and password to log in. (The default administrator username is “admin” and the default random password can be found on the sticker on the GWN7800 switch).

Configure using GWN.Cloud

Type https://www.gwn.cloud in the browser, and enter the account and password to login the cloud platform. If you don’t have an account, please register first or ask the administrator to assign one for you.

Login using the Web UI

The GWN780x(P) embedded Web server responds to HTTPS GET/POST requests. Embedded HTML pages allow users to configure the device through a Web browser such as Microsoft IE, Mozilla Firefox, or Google Chrome.

GWN780x(P) WEB GUI Page
  1. A PC uses a network cable to correctly connect any RJ45 port of the switch.
  2. Set the Ethernet (or local connection) IP address of the PC to 192.168.0.x (“x” is any value between 1-253), and the subnet mask to 255.255.255.0, so that it is in the same network segment with the switch IP address. If DHCP is used, this step could be skipped.
  3. Type the switch’s default management IP address http://<gwn7800_IP> in the browser, and enter the username and password to log in. (The default administrator username is “admin” and the default random password can be found at the sticker on the GWN7800 switch).

  • Do not attempt to open, disassemble, or modify the device.
  • Do not expose this device to temperatures outside range of 0 °C to 45 °C for operating and -10 °C to 60 °C for storage.
  • Do not expose the GWN780x(P) to environments outside of the following humidity range: 10-90% RH (non-condensing).
  • Do not power cycle your GWN780x(P) during system boot up or firmware upgrade. You may corrupt firmware images and cause the unit to malfunction.

The GNU GPL license terms are incorporated into the device firmware and can be accessed via the Web user interface of the device at my_device_ip/gpl_license. It can also be accessed here: http://www.grandstream.com/legal/open-source-software
To obtain a CD with GPL source code information please submit a written request to info@grandstream.com

Refer to online documents and FAQ for more detailed information:
http://www.grandstream.com/our-products

For Certification, Warranty, and RMA information,
please visit www.grandstream.com


Was this article helpful?

Related Articles

Need Support?
Can’t find the answer you’re looking for? Don’t worry we’re here to help!
Contact Support

Leave a Comment