The GSC3506 is a 1-way public address SIP speaker that allows offices, schools, hospitals, apartments, and more to build powerful public address announcement solutions that expand security and communication. This robust SIP speaker offers crystal clear HD audio functionality with a high-fidelity 30-Watt HD speaker. The GSC3506 support built-in whitelists, blacklists and greylists to easily block unwanted calls, SIP and multicast paging, group paging and PTT. users can easily sculpt a state-of-the-art security and PA announcement solution. Thanks to its modern industrial design and rich features, the GSC3506 is the ideal SIP speaker for any setting.

Precautions

  • Do not attempt to open, disassemble, or modify the device.
  • Do not expose this device to temperatures outside the range of 0 °C to 45 °C in operation and -10 °C to 60 °C in storage.
  • Do not expose the GSC3506 to environments outside of the following humidity range: 10-90% RH (non-condensing).
  • Do not power cycle your GSC3506 during system boot-up or firmware upgrade. You may corrupt firmware images and cause the unit to malfunction.

PACKAGE CONTENTS

GSC3506 PORTS AND BUTTONS

NO.

Port

Label

Description

1

USB Port

USB2.0, External USB Storage

2

NET/PoE

Ethernet RJ45 port (10/100Mbps) supporting PoE/ PoE+.

3

2-Pin port

2-pin switch-in input port Alarm-in input port (Access voltage 5V to 12V)

4

Reset

Factory reset button. Press for 10 seconds to reset factory default settings.

5

Volume

Sound Volume buttons.

HARDWARE INSTALLATION

GSC3506 can be mounted on the ceiling or the Boom. Please refer to the following steps for the appropriate installation.

Ceiling Mount

  1. Drill a round hole with a diameter of 230mm or use the Mounting Hole Cut-Out Template.

Then Fix the Ceiling Bracket using the screws from the kit as shown in the illustration.

2. To ensure safety, install first the anti-fall ropes, then plug in the Ethernet and 2-pin cables.

Note

The anti-fall rope diameter must be less than 5mm, and the pulling force must be greater than 25kgf.

3. Open the front cover with a flat-head screwdriver.

4. Align the device with the hole and push it up slowly with two hands.

Note

Avoid pressing the horn with your hands.

5. Use a screwdriver and gently rotate clockwise the screws marked as (1), (2), (3), and (4) in the step 5 illustration.

Note

If you use an electric drill, make sure to adjust it to the minimum speed gear first.

6. Align the notch on the front cover with the notch on the device, and press the whole front cover to ensure that each buckle is fastened.

Boom Mount

  1. Fix the Boom in the ceiling.

2. To ensure safety, install first the anti-fall ropes.

Note

The anti-fall rope diameter must be less than 5mm, and the pulling force must be greater than 25kgf.

3. Attach the Boom with the GSC3506 ceiling hole and rotate to fix it in place.

4. Plug in the Ethernet and 2-pin cables.

POWERING AND CONNECTING GSC3506

GSC3506 can be powered on using PoE/PoE+ switch or PoE injector using the following steps:

Step 1: Plug an RJ45 Ethernet cable into the network port of the GSC3506.

Step 2: Plug the other end into the power over Ethernet (PoE) switch or PoE injector.

Connecting Wiring Seat

GSC3506 supports to connect a “Normal Key” to 2-pin port via Wiring Seat.

Step 1: Take the wiring seat from the install kits.

Step 2: Connect the Normal Key with the wiring seat (as shown in the illustration on the right).

ACCESSING THE CONFIGURATION INTERFACE

A computer connected to the same network as the GSC3506 can discover and access its configuration interface using its MAC address :

  1. Locate the MAC address on the MAC tag of the unit, which is on the undersideof the device, or on the package.
  2. From a computer connected to same network as the GSC3506, type in thefollowing address using the GSC3506’s MAC address on your browser: http://gsc_.local

Example: if a GSC3506 has the MAC address C0:74:AD:11:22:33, this unit can be accessed by typing http://gsc_c074ad112233.local on the browser.