Overview

GSC3505 is a one-way SIP Intercom Speaker and GSC3510 is a two-way full-duplex SIP intercom speaker/microphone, both featuring one 100Mbps Ethernet port with PoE/PoE+, integrated dual-band 2.4G/5G Wi-Fi, integrated Bluetooth, high fidelity 8W speaker and a multi-purpose input port supporting a wide range of peripherals, 3 directional microphones with Multichannel Microphone Array Design (MMAD) available for GSC3510 only. Both GSC3505 and GSC3510 with their Hi-Fi speaker delivers full-band audio, while GSC3510 adds a state-of-art microphone array with pickup distance up to 4.2 meters. The built-in whitelist and blacklist features enable easy filtering of unwanted calls from the Internet. Its modern industrial design and rich features make it ideal for classrooms, hospitals, apartments, dormitories and much more.

Precautions:

  • Do not attempt to open, disassemble, or modify the device.
  • Do not expose this device to temperatures outside range of 0 °C to 40 °C in operation and -10 °C to 60 °C in storage.
  • Do not expose the GSC3505/GSC3510 to environments outside of the following humidity range: 10-90% RH (non-condensing).
  • Do not power cycle your GSC3510/GSC3505 during system boot up or firmware upgrade. You may corrupt firmware images and cause the unit to malfunction.

Package Contents

GSC3505/GSC3510 Ports

PortLabelDescription
ResetFactory reset button.
Press for 10 seconds to reset the factory default settings.
NET/PoEEthernet RJ45 port (10/100Mbps) supporting PoE/PoE+.
2-pin Port2-pin multi-purpose input port.

Hardware Installation

GSC3505/GSC3510 can be mounted on the wall or ceiling. Please refer to the following steps for the appropriate installation.

Wall Mount

  1. Locate the equipment holder on the desired position with arrow up. Drill three holes on the wall referring to the positions of holes on the metal bracket.
  1. Fix the metal bracket on the wall by expansion screws.
  1. Align the position line on device’s back cover with the positioning slot.
  1. Rotate the device clockwise until it is locked on the right position.

Ceiling Mount

  1. Put the ceiling mounting (metal bracket) in the ceiling’s center and mark the position of the three screw holes.
  2. Drill a round hole with a diameter of 18mm for Ethernet cable. The distance between its center and the highlighted hole on the plastic bracket should be 35mm.
  1. Fix the plastic and metal brackets on the ceiling with flat-head screws and locknuts. Then place an Ethernet cable pass through the 18mm-round hole.
  1. Align the position line on device’s back cover with the positioning slot.
  1. Rotate the device clockwise until it is locked on the right position.

Anti-theft Installation

After the device is assembled with the metal bracket support on the wall or ceiling, use the anti-detachable screw (M3 x 15) in order to prevent theft.

Powering and Connecting GSC3505/GSC3510

GSC3505/GSC3510 can be powered on using PoE/PoE+ switch or PoE injector using following steps:

Step 1: Plug an RJ45 Ethernet cable into the network port of the GSC3505/GSC3510.

Step 2: Plug the other end into the power over Ethernet (PoE) switch or PoE injector.

Connecting Wiring Seat

GSC3505/GSC3510 support to connect a “Key & LED” or “Normal Key” to 2-pin port via Wiring Seat.

Step 1: Take the wiring seat from the install kits.

Step 2: Connect the Key & LED or Normal Key with the wiring seat (as shown in the illustration on the
right).

This port supports the parallel connection of an incandescent lamp (with less than 1W) or an LED lamp (with less than 100mA)

Accessing the Configuration Interface

A computer connected to the same network as the GSC3505/GSC3510 can discover and access its configuration interface using its MAC address:

  1. Locate the MAC address on the MAC tag of the unit, which is on the underside of the device, or on the package.
  2. From a computer connected to same network as the GSC3505/GSC3510, type in the following address using the GSC3505/GSC3510’s MAC address on your browser: http://gsc_<mac>.local

For example: if a GSC3505/GSC3510 has the MAC address C0:74:AD:11:22:33, this
unit can be accessed by typing http://gsc_c074ad112233.local on the browser.

Note:

  • The admin username is “admin”.
  • The default admin password can be found on the sticker on the back of the unit.

The GSC3505/GSC3510 is not pre-configured to support or make emergency calls to any type of hospital, law enforcement agency, medical care unit (“Emergency Service(s)”) or any other kind of Emergency Service. You must make additional arrangements to access Emergency Services. It is your responsibility to purchase an SIP-compliant Internet telephone service, properly configure the GSC3505/GSC3510 to use that service, and periodically test your configuration to confirm that it works as you expect. It is also your responsibility to purchase traditional wireless or landline telephone services to access Emergency Services.

GRANDSTREAM DOES NOT PROVIDE CONNECTIONS TO EMERGENCY SERVICES VIA THE GSC3505/GSC3510. NEITHER GRANDSTREAM NOR ITS OFFICES, EMPLOYEES, OR AFFILIATES MAY BE HELD LIABLE FOR ANY CLAIM, DAMAGE, OR LOSS, AND YOU HEREBY WAIVE ANY AND ALL SUCH CLAIMS OR CAUSES OF ACTION ARISING FROM OR RELATING TO YOUR INABILITY TO USE THE GSC3505/GSC3510 TO CONTACT EMERGENCY SERVICES, AND YOUR FAILURE TO MAKE ADDITIONAL ARRANGEMENTS TO ACCESS EMERGENCY SERVICES IN ACCORDANCE WITH THE IMMEDIATELY PRECEDING PARAGRAPH.

For Certification, Warranty, and RMA information, please visit
www.grandstream.com


Was this article helpful?

Related Articles

Need Support?
Can’t find the answer you’re looking for? Don’t worry we’re here to help!
Contact Support

Leave a Comment